Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Braz Dent J ; 29(5): 469-474, 2018.
Artigo em Português | MEDLINE | ID: mdl-30517446

RESUMO

This study determined the reduction threshold in thickness of the dentin shade composite necessary to result in perceptible and acceptable color changes on simulated restorations. Three composite systems (Charisma Diamond, IPS Empress Direct, and Filtek Z350 XT) were evaluated using cylinder-shaped specimens built-up with dentin and enamel shades. The opacity of the composites was assessed using 1.0 mm thick specimens over black and white backgrounds. A baseline color was established for each system by combining 1.0 mm thick enamel shade with 3.0 mm of dentin shade cylinders over a dark background (n = 9). Then, the color changes (∆E00) caused by sequential 0.1 mm reductions on dentin shade cylinders were calculated. Opacity changes on dentin shade cylinders and combined enamel-dentin pair cylinders were also assessed after each thickness reduction. Polynomial regression was performed with averages of ∆E00 as a function of thickness of dentin shade cylinders; and acceptability (∆E = 1.77) and perceptibility (∆E = 0.81) thresholds were calculated. Linear regressions were also performed for ∆E00 as function of opacity of dentin shade cylinders and combined enamel-dentin pair of cylinders. Except for Charisma, enamel shades presented the lowest opacity than dentin one. Perceptible and acceptable color changes were observed for dentin shade cylinders thinner than 2.0-2.4 mm and 1.1-1.4 mm, respectively, were used. No difference among the composite systems was observed. In conclusion, reductions on dentin shade composite lower than 0.6-mm did not yield perceptible color changes, and clinically significant color changes only were observed within reductions higher than 1.6-mm.


Este estudo objetivou determinar o limiar de redução na espessura do compósito de cor da dentina necessário para resultar em mudanças de cor perceptíveis e aceitáveis em restaurações simuladas. Três sistemas de compósitos (Charisma Diamond, IPS Empress Direct e Filtek Z350 XT) foram avaliados utilizando corpos-de-prova cilíndricos construídos com cores de dentina e esmalte. A opacidade dos compósitos foi avaliada usando cilindros de 1,0 mm de espessura sobre fundo preto e branco. Uma cor inicial padrão foi estabelecida para cada sistema pela combinação de esmalte de 1,0 mm de espessura com 3,0 mm de cilindros de resina na cor de dentina sobre um fundo escuro (n = 9). Em seguida, foram calculadas as alterações de cor (∆E00) causadas por reduções sequenciais de 0,1 mm nos cilindros de resina na cor de dentina. Mudanças de opacidade em cilindros na cor de dentina e cilindros combinados de esmalte e dentina foram também avaliadas após cada redução de espessura. Regressão polinomial foi realizada com médias de ∆E00 em função da espessura dos cilindros na cor de dentina; e os limiares de aceitabilidade (∆E00 = 1,77) e perceptibilidade (∆E00 = 0,81) foram calculados. Regressões lineares também foram realizadas para ∆E00 em função da opacidade dos cilindros na cor de dentina e do par combinado de cilindros de esmalte-dentina. Com exceção da Charisma, os compósitos de esmalte apresentaram menor opacidade do que os de dentina. Alterações de cor perceptíveis e aceitáveis foram observadas quando os cilindros na cor de dentina foram mais finos que 2,0-2,4 mm e 1,1-1,4 mm, respectivamente. Nenhuma diferença entre os sistemas compostos foi observada. Em conclusão, reduções no compósito de dentina menor que 0,6 mm não produziu mudanças de cor perceptíveis, e mudanças de cor clinicamente significantes apenas foram observadas com reduções maiores que 1,6 mm.


Assuntos
Resinas Compostas/química , Materiais Dentários/química , Dentina/química , Silicatos de Alumínio , Porcelana Dentária , Estética Dentária , Técnicas In Vitro , Teste de Materiais , Fenômenos Ópticos , Propriedades de Superfície
2.
Braz. dent. j ; 29(5): 469-474, Sept.-Oct. 2018. tab, graf
Artigo em Português | LILACS | ID: biblio-974186

RESUMO

Resumo Este estudo objetivou determinar o limiar de redução na espessura do compósito de cor da dentina necessário para resultar em mudanças de cor perceptíveis e aceitáveis em restaurações simuladas. Três sistemas de compósitos (Charisma Diamond, IPS Empress Direct e Filtek Z350 XT) foram avaliados utilizando corpos-de-prova cilíndricos construídos com cores de dentina e esmalte. A opacidade dos compósitos foi avaliada usando cilindros de 1,0 mm de espessura sobre fundo preto e branco. Uma cor inicial padrão foi estabelecida para cada sistema pela combinação de esmalte de 1,0 mm de espessura com 3,0 mm de cilindros de resina na cor de dentina sobre um fundo escuro (n = 9). Em seguida, foram calculadas as alterações de cor (∆E00) causadas por reduções sequenciais de 0,1 mm nos cilindros de resina na cor de dentina. Mudanças de opacidade em cilindros na cor de dentina e cilindros combinados de esmalte e dentina foram também avaliadas após cada redução de espessura. Regressão polinomial foi realizada com médias de ∆E00 em função da espessura dos cilindros na cor de dentina; e os limiares de aceitabilidade (∆E00 = 1,77) e perceptibilidade (∆E00 = 0,81) foram calculados. Regressões lineares também foram realizadas para ∆E00 em função da opacidade dos cilindros na cor de dentina e do par combinado de cilindros de esmalte-dentina. Com exceção da Charisma, os compósitos de esmalte apresentaram menor opacidade do que os de dentina. Alterações de cor perceptíveis e aceitáveis foram observadas quando os cilindros na cor de dentina foram mais finos que 2,0-2,4 mm e 1,1-1,4 mm, respectivamente. Nenhuma diferença entre os sistemas compostos foi observada. Em conclusão, reduções no compósito de dentina menor que 0,6 mm não produziu mudanças de cor perceptíveis, e mudanças de cor clinicamente significantes apenas foram observadas com reduções maiores que 1,6 mm.


Abstract This study determined the reduction threshold in thickness of the dentin shade composite necessary to result in perceptible and acceptable color changes on simulated restorations. Three composite systems (Charisma Diamond, IPS Empress Direct, and Filtek Z350 XT) were evaluated using cylinder-shaped specimens built-up with dentin and enamel shades. The opacity of the composites was assessed using 1.0 mm thick specimens over black and white backgrounds. A baseline color was established for each system by combining 1.0 mm thick enamel shade with 3.0 mm of dentin shade cylinders over a dark background (n = 9). Then, the color changes (∆E00) caused by sequential 0.1 mm reductions on dentin shade cylinders were calculated. Opacity changes on dentin shade cylinders and combined enamel-dentin pair cylinders were also assessed after each thickness reduction. Polynomial regression was performed with averages of ∆E00 as a function of thickness of dentin shade cylinders; and acceptability (∆E = 1.77) and perceptibility (∆E = 0.81) thresholds were calculated. Linear regressions were also performed for ∆E00 as function of opacity of dentin shade cylinders and combined enamel-dentin pair of cylinders. Except for Charisma, enamel shades presented the lowest opacity than dentin one. Perceptible and acceptable color changes were observed for dentin shade cylinders thinner than 2.0-2.4 mm and 1.1-1.4 mm, respectively, were used. No difference among the composite systems was observed. In conclusion, reductions on dentin shade composite lower than 0.6-mm did not yield perceptible color changes, and clinically significant color changes only were observed within reductions higher than 1.6-mm.


Assuntos
Resinas Compostas/química , Materiais Dentários/química , Dentina/química , Propriedades de Superfície , Técnicas In Vitro , Teste de Materiais , Porcelana Dentária , Estética Dentária , Fenômenos Ópticos , Silicatos de Alumínio
3.
Braz. dent. j ; 29(1): 88-92, Jan.-Feb. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-888729

RESUMO

Abstract This study evaluated the effects of tooth bleaching with high-concentration of hydrogen peroxide on alterations of translucency parameter (TP) and color of dentin and enamel. The crown of five human molars was sectioned into four slices parallel to buccal surface. The dentin of external slices containing buccal/ lingual enamel was fully removed with diamond bur; while these slices were used to assess alterations on enamel. Alterations on dentin were assessed into the center of internal slices. The color of specimens was measured over white and black backgrounds using a spectrophotometer (CieL*a*b) at baseline, allowing to calculate the TP by difference between the color measured over each background. Specimens were submitted to three 15-min applications of 35% hydrogen peroxide followed by their storage in water for one-week. Afterwards, the color measurements were repeated at both backgrounds. Color (∆L, ∆a, ∆b and ∆E) and translucency (∆TP) changes were calculated and data individually analyzed by T-test (α = 0.05). Influence of hard tissue and assessment time on each color parameter was also analyzed by 2-way repeated measure ANOVA (α = 0.05). Tooth bleaching resulted in increased lightness for the enamel, whereas no alteration on this parameter occurred for dentin. No difference between the tooth hard tissues was observed regards the other color parameters and ∆E. A slightly reduction on TP was observed only for the enamel. In conclusion, 35% hydrogen peroxide caused similar color and translucency changes on dentin and enamel.


Resumo Este estudo avaliou os efeitos do clareamento dental com peróxido de hidrogênio em alta concentração nas alterações do parâmetro de translucidez (PT) e cor da dentina e esmalte. A coroa de cinco molares humanos foi seccionada em quatro fatias paralelas à superfície vestibular. A dentina das fatias externas contendo esmalte vestibular/ lingual foi totalmente removida com ponta diamantada, sendo estas fatias usadas para verificar as alterações no esmalte. Alterações na dentina foram verificadas no centro das fatias internas. A cor das amostras foi mensurada sobre fundos preto e branco usando um espectrofotômetro (CieL*a*b) no início, permitindo calcular o PT pela diferença de cor medida sobre cada fundo. As amostras foram submetidas a três aplicações de 15 minutos de peróxido de hidrogênio a 35% seguido pelo seu armazenamento em água por uma semana. Após isto, as mensurações de cor foram repetidas em ambos os fundos. Mudanças de cor (∆L, ∆a, ∆b e ∆E) e translucidez (∆PT) foram calculadas e os dados analisados pelo Teste T (α = 0,05). A influência do tecido duro e do momento de avaliação em cada parâmetro de cor foi também analisado através de ANOVA de duas vias para medidas repetidas (α = 0,05). O clareamento dental resultou em maior luminosidade (∆L) para o esmalte, enquanto que nenhuma alteração neste parâmetro ocorreu para a dentina. Nenhuma diferença entre os tecidos duros dentais foi observada em relação aos outros parâmetros de cor e ∆E. Uma leve redução na PT foi observada apenas para o esmalte. Como conclusão, peróxido de hidrogênio a 35% causou similar alteração de cor e translucidez no esmalte e na dentina.


Assuntos
Humanos , Cor , Esmalte Dentário/química , Dentina/química , Peróxido de Hidrogênio/química
4.
Braz Dent J ; 29(1): 88-92, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29267531

RESUMO

This study evaluated the effects of tooth bleaching with high-concentration of hydrogen peroxide on alterations of translucency parameter (TP) and color of dentin and enamel. The crown of five human molars was sectioned into four slices parallel to buccal surface. The dentin of external slices containing buccal/ lingual enamel was fully removed with diamond bur; while these slices were used to assess alterations on enamel. Alterations on dentin were assessed into the center of internal slices. The color of specimens was measured over white and black backgrounds using a spectrophotometer (CieL*a*b) at baseline, allowing to calculate the TP by difference between the color measured over each background. Specimens were submitted to three 15-min applications of 35% hydrogen peroxide followed by their storage in water for one-week. Afterwards, the color measurements were repeated at both backgrounds. Color (∆L, ∆a, ∆b and ∆E) and translucency (∆TP) changes were calculated and data individually analyzed by T-test (α = 0.05). Influence of hard tissue and assessment time on each color parameter was also analyzed by 2-way repeated measure ANOVA (α = 0.05). Tooth bleaching resulted in increased lightness for the enamel, whereas no alteration on this parameter occurred for dentin. No difference between the tooth hard tissues was observed regards the other color parameters and ∆E. A slightly reduction on TP was observed only for the enamel. In conclusion, 35% hydrogen peroxide caused similar color and translucency changes on dentin and enamel.


Assuntos
Cor , Esmalte Dentário/química , Dentina/química , Peróxido de Hidrogênio/química , Humanos
5.
Braz Dent J ; 28(5): 612-617, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29215687

RESUMO

The aim of the present study was to evaluate the effect of prior microabrasion on the teeth color change and tooth bleaching effectiveness. Eight sound molars were mesio-distally sectioned and the halves were randomly allocated to receive enamel microabrasion or non-abrasion (control) in one of surfaces (buccal or lingual), while the remaining surface received the other treatment. The tooth color on baseline was evaluated by spectrophotometer (CieL*a*b system). After the microabrasion procedure, the tooth color was measured again. Following, the specimens were bleached with 35% hydrogen peroxide for two sessions with one-week interval. The color was re-evaluated 7 days after each section and 30 days after the second session. The effect of enamel microabrasion on color changes was evaluated by paired T-test. Deltas L*, a*, b*, and E were calculated and data submitted to 2-way repeated measure ANOVA followed by Tukey`s test. Paired T-test was also used to assess possible differences on the ultimate color achieved after tooth bleaching. Enamel microabrasion reduced the lightness and increased the redness of specimens. Specimens that received microabrasion presented higher values of ∆L* than control after each bleaching procedure; and higher ∆a* after the 2nd bleaching session. However, the prior enamel microabrasion did not affect the ultimate values of color parameters. Despite enamel microabrasion have modified the tooth color, this procedure did not affect the ultimate results achieved with tooth bleaching using a high-concentrated hydrogen peroxide.


Assuntos
Microabrasão do Esmalte , Clareamento Dental/métodos , Humanos , Descoloração de Dente
6.
Braz. dent. j ; 28(5): 612-617, Sept.-Oct. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-888688

RESUMO

Abstract The aim of the present study was to evaluate the effect of prior microabrasion on the teeth color change and tooth bleaching effectiveness. Eight sound molars were mesio-distally sectioned and the halves were randomly allocated to receive enamel microabrasion or non-abrasion (control) in one of surfaces (buccal or lingual), while the remaining surface received the other treatment. The tooth color on baseline was evaluated by spectrophotometer (CieL*a*b system). After the microabrasion procedure, the tooth color was measured again. Following, the specimens were bleached with 35% hydrogen peroxide for two sessions with one-week interval. The color was re-evaluated 7 days after each section and 30 days after the second session. The effect of enamel microabrasion on color changes was evaluated by paired T-test. Deltas L*, a*, b*, and E were calculated and data submitted to 2-way repeated measure ANOVA followed by Tukey`s test. Paired T-test was also used to assess possible differences on the ultimate color achieved after tooth bleaching. Enamel microabrasion reduced the lightness and increased the redness of specimens. Specimens that received microabrasion presented higher values of ∆L* than control after each bleaching procedure; and higher ∆a* after the 2nd bleaching session. However, the prior enamel microabrasion did not affect the ultimate values of color parameters. Despite enamel microabrasion have modified the tooth color, this procedure did not affect the ultimate results achieved with tooth bleaching using a high-concentrated hydrogen peroxide.


Resumo O objetivo deste estudo foi avaliar o efeito da microabrasão prévia na alteração de cor dos dentes e na efetividade do clareamento dental. Oito molares hígidos foram mesio-distalmente seccionados e as metades foram aleatoriamente alocadas para receberem microabrasão do esmalte ou nenhuma abrasão (controle) em uma das faces (vestibular ou lingual), enquanto que a face remanescente recebeu o outro tratamento. A cor inicial dos dentes foi avaliada com um espectrofotômetro (sistema CieL*a*b). Após o procedimento de microabrasão, a cor do dente foi reavaliada. Em seguida, as amostras foram clareadas com peróxido de hidrogênio a 35% por duas sessões com uma semana de intervalo. A cor foi reavaliada 7 dias após cada sessão e 30 dias após a segunda sessão. O efeito da microabrasão do esmalte na mudança de cor foi avaliado pelo teste T pareado. Deltas L*, a*, b* e E foram calculados e os dados submetidos a ANOVA de duas vias para medidas repetidas e teste de Tukey. Teste T pareado também foi usado para verificar possíveis diferenças na cor final alcançada com o clareamento dental. A microabrasão do esmalte reduziu a luminosidade e aumentou a tonalidade vermelha nas amostras. Amostras submetidas a microabrasão apresentaram maiores valores de ∆L* que o controle após cada procedimento clareador, e maior ∆a* após a 2ª sessão de clareamento. Entretanto, a microabrasão prévia do esmalte não afetou os valores finais dos parâmetros de cor. Apesar da microabraão do esmalte ter alterado a cor dental, este procedimento não afetou os resultados finais alcançados com o clareamento dental usando alta concentração de peróxido de hidrogênio.


Assuntos
Humanos , Microabrasão do Esmalte , Clareamento Dental/métodos , Descoloração de Dente